Here are a set of question to ask when facing problems with the
Dongle.
Q: Which brand is your Dongle?
A: Rainbow has some problems with a series
Q: Is the Workbench running on Win98 or NT?
A: If running on Win98, the sentinel driver has to be installed
manually.
Q: Is the sentinel driver installed (manually) correctly
from the CD ROM?
A: The sentinal driver installation files are situated on the CD
ROM under the directory \Sentinel, and were not installed with the
Workbench
Q: Is it a "tiny" Dongle?
A: A series of "tiny" Dongle has a problem and could be
de-programmed automatically (has to be changed).
If your question is not answered, please complete the following in
order to send more information to Rainbow.
Q: The PC used is it a DeskTop or a Notebook? If notebook,
what is the brand?
A: Rainbow Key has compatibility problem with "WinBook XP5"
notebook computer.
Q: What is the parallel port configuration? (look into the
Bios) EPP 1.5... or ECP or ECP+EPP?
A: There are some problems using configuration ECP...
Q: Check the version of the sentinel Driver in the
Registry
A: Use REGEDIT.exe, to check:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Sentinel\current\versionString=5.38.
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\VXD\sentinel\current\versionstring=5.38.2